Company Products Services Distributors FAQ's Contact Home
StatSpin VT
VET Express
Hematocrit Systems
CytoFuge
CenSlide
Supplies

StatSpin VT | VET Express | CenSlide | CytoFuge

StatSpin VT
Supplies listed below may be used on the StatSpin MP, RP and CritSpin.

Supplies

Blood Separation
StatSpin's Prepared Microtubes are quick and easy to use -- serum (red top), plasma (green top) or gel tube (clear top). Quality separations in only 30-90 seconds. Patented PlasmaRotor (yellow cap) produces gel-separated plasma from up to 3 mL of blood in just 30 seconds to 2.5 minutes depending upon application.
Microtubes fit RT12 Tube Rotor.

TP1H 1.3 mL Microtube, plasma, with heparin, 100/pk.
TP1U 1.3 mL Microtube, serum, with clot activator,100/pk.
TP5G 0.5 mL Microtube, untreated with gel barrier, 50/pk.
RD01S 3.0 mL PlasmaRotor with gel and cap, 50/pk.

LipoClear®
Simple, effective way to clear lipemia from 0.5 or 1.5 mL of serum or plasma. Five minute room temperature incubation followed by a 90 second cycle in your StatSpin (a bit longer in other centrifuges). Convenient predispensed reagent tubes, non-toxic, one-year shelf life if kept refrigerated. Tubes fit RT12 Tube Rotor; can also be used in VET Express and other centrifuge brands.

LC40 LipoClear Reagent Tubes for 0.5 mL samples, 40/pk.
LC10 LipoClear Reagent Tubes for 0.5 mL samples, 10/pk.
LC15 LipoClear Reagent Tubes for 1.5 mL samples, 40/pk.
   

Urine Sediment
Unique micro-method correlates with standard procedure. Only 1.5 mL of urine is needed; precalibrated conical tube with flip cap makes filling and decanting easy. 45 second spin time in your StatSpin. For use in RT12 Tube Rotor.

TU15 Precalibrated urine tubes, 1.5 mL with flip cap, 50/pk.
TU15-10 As above, 500/pk.
PF35 Accessory fine tipped pipette, 100/pk.
   

Microhematocrits
Accurate and easy crits in two minutes from as little as 10 uL of blood! Choose glass or easy to read SafeCrit® plastic tubes, plain or heparinized. These tubes feature rapid capillary action and have a two-year shelf life. For use in RH12 HCT Rotor.

HT9H Glass capillary tubes, heparinized, 100/vial.  
HT9H-10 As Above, 100 tubes/vial, 10 vials.  
HT9U Glass capillary tubes, untreated, 100/vial.  
HT9U-10 As Above, 100 tubes/vial, 10 vials.  
HP8H Plastic capillary tubes, heparinized, 100/vial.  
HP8H-10 As Above, 100 tubes/vial, 10 vials.  
HP8U Plastic capillary tubes, untreated, 100/vial.  
HP8U-10 As Above, 100 tubes/vial, 10 vials.  

Accessories

Tube Rotors

RT12 Microtube Rotor, accepts 2 tubes. Precision fabricated high speed rotor accepts a variety of StatSpin tubes as well as standard 1.5-2 mL microcentrifuge tubes (neck supported only). For StatSpin models SSVT, SSMP and SSRP.
RM02 Microtainer Rotor, accepts 2 tubes. Similar to RT12 Rotor but accepts BD Microtainers® only (8 mm diameter). For StatSpin models SSVT, SSMP, and SSRP.

Microhematocrit Rotor

Accepts up to 12 StatSpin glass or plastic capillary tubes (40mm). Includes carbon-fiber retaining ring for durability and easy to use transparent screw-on lid. For StatSpin models SSVT, SSMP and CS02.

 
RH12 12-place microhematocrit rotor with transparent lid
01-2002-04 Replacement cushions for RH12 Rotor, 12/pk.
01-2002-05 Replacement transparent lid with knob.
 

CritSpin Digital Hematocrit Reader
 

Increases productivity of any StatSpin centrifuge with hematocrit capability. Accepts RH12 Rotor directly … no need to transfer tubes. Easy to use pointer and bright illumination make reading tubes simple. For StatSpin models SSVT, SSMP and CS02.

CSD2 CritSpin Digital Hematocrit Reader with power supply and adapter for 75 mm capillary tubes
 

VET Express Accessories and Supplies

   
SV01 Replacement inserts for 5 mL tubes (13x75 mm, 10.25x68 mm), 4/pk.
SV02 Inserts for 3 mL tubes (10.25x64 mm), 4/pk.
SV03 Inserts for 0.5-2 mL tubes (10.25x47 mm, Microtainers), 4/pk.
SV04 Inserts for 1.5-2 mL microtubes (e.g. LipoClear), 4/pk.
SV05 Inserts for 2mL BD Microtainers.
DL01 Replacement chamber liners, 10/pk.
RTX4A Replacement 4-place rotor with SV01 inserts.

Supplies

LipoClear®

Simple, effective way to clear lipemia from 0.5 or 1.5 mL of serum or plasma. Five minute room temperature incubation followed by a 180 second cycle in the VET Express. Convenient predispensed reagent tubes, non-toxic, one-year shelf life from date of manufacture. (refrigeration 2-8oC required)

LC40 LipoClear Reagent Tubes for 0.5 mL samples, 40/pk.
LC10 LipoClear Reagent Tubes for 0.5 mL samples, 10/pk.
LC15 LipoClear Reagent Tubes for 1.5 mL samples, 40/pk.
   

CenSlide 2000 Supplies and Accessories

Supplies

2C-2000-012 CenSlide Tubes with Caps, 5mL, 120/pack.
2C-2000-240
As Above, 2400/case (20 boxes of 120 each).
   

Accessories



2C-3000-001


StakRak,
1 each, accommodates up to 12 CenSlide Tubes for both filling and transport.

2C-5600-001
CenSlide Tube Holder,
Pack of 2, holds CenSlide Tube in-place on Microscope stage to allow for easy viewing
2C-4940-001
1 each, For American Optical Microscopes, a physically short objective with a long working distance
2C-4950-001
1 each, for non-American Optical Microscopes, long working distance objective to fit non-AO scopes

CytoFuge 2 Accessories and Supplies

Accessories

CFRT-2
Molded high-impact, high-Strength, plastic 4-position rotor for use with the StatSpin CytoFuge or CytoFuge 2. Rotor holds two of four CytoFuge Cell Concentrators or Filter Concentrators. Supplied with cover and sealing gasket. Spins in the CytoFuge 2 at speeds up to 4,400 rpm (1060 x g). Autoclavable.
CFRC Replacement cover for CFRT or CFRT-2 Rotors (not shown).

Supplies

CytoFuge 2 Filter Concentrators

Easy to use device allows cells to gently concentrate in a 7mm diameter area on the slide while supernatant is simultaneously absorbed by a filter card. Accepts 50-400 ul of sample; produces cell monolayer presentations of excellent quality.

FF01 Filter Concentrator, removes fluid as spinning, 48/ case
FFR1 Filter Concentrator with replaceable filter cards, 20 plastic concentrators (reusable) with 200 filter cards (disposable)

CytoFuge 2 Cell Concentrators

Three-chamber Cell Concentrators allow for three different concentrators of the same specimen to be spun simultaneously on one slide (up to 200uL fluid per chamber), or different stains applied to same specimen. One chamber Cell Concentrator processes up to 0.8 mL fluid. Both bleach compatible.

CC01,CCRI One-chamber Cell Concentrator with silicon gasket. 10/bag.
CC03,CCR3 Three-chamber Cell Concentrator with silicon gasket,10/bag.
CLIP Replacement stainless steel clips (for use with Cell Concentrators), 10/bag.
BP01 Replacement backing plate for Cell Concentrators, 10 bag.
GK01 Disposable silicon gaskets for use with chamber Cell Concentrators, 100/ bag.
GK03 Disposable silicon gaskets for use with three chamber Cell Concentractors, 100/bag.

StatSpin, Inc.
60 Glacier Drive
Westwood, MA 02090
email: info1@StatSpin.com

Tel: 800-782-8774
      781-551-0100
Fax: 781-551-0036
Web: www.StatSpinVet.com

© 2001 - 2003 StatSpin, Inc. All Rights Reserved